OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
FS#6871 — SBG Network
Scheduled Maintenance Report for Network & Infrastructure
Completed
We implement the new architecture:
Now there will be a couple of ASR9000 and nexus5000 to which which the chassis 6500 will be connected.
All the traffic will flow through the ASR that will route the traffic to the backbone (TH2 / GSW and FRA).


Update(s):

Date: 2012-07-05 23:55:07 UTC
We are switching th2-g1-a9 on sbg-g1-a9.

Date: 2012-07-05 23:54:28 UTC
We are switching fra-5-6k on sbg-g2-a9.

Date: 2012-07-05 23:54:02 UTC
We are starting.

Date: 2012-07-05 23:53:41 UTC
We will run the ASRs at 00:00 (CEST).
That's why traffic between SBG and fra-5-6k and then between SBG and th2-g1-a9 will be temporarily interrupted.

Date: 2012-07-05 23:49:55 UTC
ASRs are also connected.

We are activating the OSPF in order to make the equipment accessible by the network.

Date: 2012-07-05 23:49:36 UTC
n5 are connected now.

Date: 2012-07-05 23:49:16 UTC
We are connecting the n5.
Posted Jun 12, 2012 - 10:33 UTC