OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
FS#6592 — vss-3/3b, vss-5a/5b routing
Incident Report for Network & Infrastructure
Resolved
These routers are affected by a routing problem. When an \"event\" occurs on the backbone (interruption of a 10G link for example), routers enter into an unstable state at the level of GLBP (Routing Redundancy Protocol) which results in intermittent traffic interruptions to clients networks.
We are working on the problem.




Update(s):

Date: 2012-04-28 20:54:51 UTC
We modified a parameter in the OSPF
in order to decrease the calculus load.
The routers seem to be stable.

Date: 2012-04-13 17:33:37 UTC
We have restarted a new couple of routers urgently : vss-8a et 8b. We wil switch networks 176.31.224 and 226 on it in order to decrease the load on vss-5a/b.
Posted Apr 13, 2012 - 11:24 UTC