FS#2631 — FS#6592 — vss-3/3b, vss-5a/5b routing

Attached to Project— Network
Incident
Whole Network
CLOSED
100%
These routers are affected by a routing problem. When an "event" occurs on the backbone (interruption of a 10G link for example), routers enter into an unstable state at the level of GLBP (Routing Redundancy Protocol) which results in intermittent traffic interruptions to clients networks.
We are working on the problem.



Date:  Saturday, 28 April 2012, 22:54PM
Reason for closing:  Done
Comment by OVH - Friday, 13 April 2012, 19:33PM

We have restarted a new couple of routers urgently : vss-8a et 8b. We wil switch networks 176.31.224 and 226 on it in order to decrease the load on vss-5a/b.


Comment by OVH - Saturday, 28 April 2012, 22:54PM

We modified a parameter in the OSPF
in order to decrease the calculus load.
The routers seem to be stable.