Get webhook notifications whenever Network & Infrastructure creates an incident, updates an incident, resolves an incident or changes a component status.
Date: 2010-06-13 10:41:03 UTC With 4x10G /6500, it goes well as soon as a 10G port
takes on more than 300'000 packets/seconds from a N5,
nevertheless it has errors on the input.
We will ascend the errors at Cisco.
Date: 2010-06-12 07:48:47 UTC The errors still increase, yet there is no problem of MAC detection
between the cards of load repartition and the servers.
We will add a 2nd 10G port in the channels port
between the 6k and the N5. If we distribute the traffic
on 2 10G ports instead of 1, it must functions well.
Date: 2010-06-12 07:46:13 UTC On n5 we can put flowcontrol on the port channel, but not on the physical ports, and on 6K we can put flowcontrol on the physical port but not on port channel.
I love it.
Date: 2010-06-12 07:34:35 UTC We will try to check if it would be better with the flowcontrol.
Date: 2010-06-12 07:32:51 UTC We have an input packet problem on the 6000. None on the Nexus 5000.
We have restarted the p19-53-n5 then p19-54-n5.
They are in cluster so each took the other's relay. The problem persists.
The problem is on all 6K ports that are connected towards N5.