FS#1795 — FS#5771 — N5 update

Attached to Project— Dedicated Cloud
Maintenance
Roubaix 4
CLOSED
100%
We are going to put some N5 with a NX-OS beta
version that will be released end of October
and which must fix the CPU problem caused by
the PBDU packet.
Date:  Tuesday, 13 September 2011, 05:30AM
Reason for closing:  Done
Comment by OVH - Sunday, 11 September 2011, 16:46PM

Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive reset
100 yes non-disruptive rolling
106 yes non-disruptive rolling
107 yes non-disruptive rolling
108 yes non-disruptive rolling
110 yes non-disruptive rolling
111 yes non-disruptive rolling


Comment by OVH - Sunday, 11 September 2011, 16:47PM

pcc-20-n5 was updated.

pcc-20-n5# sh fex detail | i version
FEX version: 5.1(3)N1(1) [Switch version: 5.1(3)N1(1)]
FEX Interim version: 5.1(3)N1(0.254)
Switch Interim version: 5.1(3)N1(0.254)
FEX version: 5.1(3)N1(1) [Switch version: 5.1(3)N1(1)]
FEX Interim version: 5.1(3)N1(0.254)
Switch Interim version: 5.1(3)N1(0.254)
FEX version: 5.1(3)N1(1) [Switch version: 5.1(3)N1(1)]
FEX Interim version: 5.1(3)N1(0.254)
Switch Interim version: 5.1(3)N1(0.254)
FEX version: 5.1(3)N1(1) [Switch version: 5.1(3)N1(1)]
FEX Interim version: 5.1(3)N1(0.254)
Switch Interim version: 5.1(3)N1(0.254)
FEX version: 5.1(3)N1(1) [Switch version: 5.1(3)N1(1)]
FEX Interim version: 5.1(3)N1(0.254)
Switch Interim version: 5.1(3)N1(0.254)
FEX version: 5.1(3)N1(1) [Switch version: 5.1(3)N1(1)]
FEX Interim version: 5.1(3)N1(0.254)
Switch Interim version: 5.1(3)N1(0.254)


Comment by OVH - Sunday, 11 September 2011, 16:49PM

It's ok. It's stable right now.

We must work on pcc-21/22 which are full CPU and
by the same occasion we had to apply spantree.
We must cut all the ports , desactivate spantree
update and restart.


Maybe tonight.


Comment by OVH - Sunday, 11 September 2011, 16:50PM

We can update the pcc-21.

In progress.


Comment by OVH - Sunday, 11 September 2011, 16:53PM

Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive reset
100 yes non-disruptive rolling
106 yes non-disruptive rolling
107 yes non-disruptive rolling
108 yes non-disruptive rolling
110 yes non-disruptive rolling
111 yes non-disruptive rolling