Get webhook notifications whenever Network & Infrastructure creates an incident, updates an incident, resolves an incident or changes a component status.
We are rebooting the ACE. Contexts in fail-over are running on the 2nd card (rbx-s2).
Update(s):
Date: 2011-09-06 04:51:56 UTC last boot reason: SB Wdog uspace big loadavg
Date: 2011-09-06 04:51:47 UTC The card has crashed and the router restarted it
Sep 6 00:11:54 GMT: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled 'off (Reset - Module Reloaded During Download)'
Sep 6 00:11:54 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset - Module Reloaded During Download)
Sep 6 00:11:59 GMT: %DIAG-SP-3-TEST_FAIL: Module 2: TestAsicSync{ID=3} has failed. Error code = 0x76 (DIAG_QUERY_HYPERION_SYNC_ERROR)
Sep 6 00:17:19 GMT: %DIAG-SP-6-RUN_MINIMUM: Module 2: Running Minimal Diagnostics...
Sep 6 00:17:20 GMT: %DIAG-SP-6-DIAG_OK: Module 2: Passed Online Diagnostics
Sep 6 00:17:26 GMT: %OIR-SP-6-INSCARD: Card inserted in slot 2, interfaces are now online
Date: 2011-09-05 04:06:33 UTC Done.
Date: 2011-09-05 04:06:25 UTC Reloading the card only wasn't enough. After a full reboot, the card has finally booted.
The connexion problem which led us to reboot the card seemed to be fixed.
Contexts will be re-switched from rbx-s2 to rbx-s1.