FS#1669 — FS#5650 — pcc-1a et pcc-1b
Attached to Project— Dedicated Cloud
Maintenance | |
Roubaix 4 | |
CLOSED | |
![]() |
We are going to update 2 Nexus 7000 which manage the pcc.
This will fixe the bug CSCtr36441
http://status.ovh.net/?do=details&id=1625
Date: Wednesday, 03 August 2011, 13:57PMThis will fixe the bug CSCtr36441
http://status.ovh.net/?do=details&id=1625
Reason for closing: Done
pcc-1a-n7# sh system redundancy status
Redundancy mode
---------------
administrative: HA
operational: HA
This supervisor (sup-1)
-----------------------
Redundancy state: Active
Supervisor state: Active
Internal state: Active with HA standby
Other supervisor (sup-2)
------------------------
Redundancy state: Standby
Supervisor state: HA standby
Internal state: HA standby
pcc-1b-n7# sh system redundancy status
Redundancy mode
---------------
administrative: HA
operational: HA
This supervisor (sup-1)
-----------------------
Redundancy state: Active
Supervisor state: Active
Internal state: Active with HA standby
Other supervisor (sup-2)
------------------------
Redundancy state: Standby
Supervisor state: HA standby
Internal state: HA standby
# sh vpc brief
Peer status : peer adjacency formed ok
vPC keep-alive status : peer is alive
Configuration consistency status: success
Type-2 consistency status : success
vPC role : primary, operational secondary
# sh vpc brief
Peer status : peer adjacency formed ok
vPC keep-alive status : peer is alive
Configuration consistency status: success
Type-2 consistency status : success
vPC role : secondary, operational primary
Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive rolling
2 yes non-disruptive rolling
3 yes non-disruptive rolling
4 yes non-disruptive rolling
5 yes non-disruptive reset
6 yes non-disruptive reset
7 yes non-disruptive rolling
8 yes non-disruptive rolling
9 yes non-disruptive rolling
10 yes non-disruptive rolling
pcc-1a-n7 is updated
2011 Aug 2 20:48:56 pcc-1b-n7 %VPC-2-VPC_ISSU_START: Peer vPC switch ISSU start, locking configuration
2011 Aug 2 21:26:17 pcc-1b-n7 %VPC-2-VPC_ISSU_END: Peer vPC switch ISSU end, unlocking configuration
we are attacking the pcc-1b-n7
Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive rolling
2 yes non-disruptive rolling
3 yes non-disruptive rolling
4 yes non-disruptive rolling
5 yes non-disruptive reset
6 yes non-disruptive reset
7 yes non-disruptive rolling
8 yes non-disruptive rolling
9 yes non-disruptive rolling
10 yes non-disruptive rolling
pcc-1b-n7 is updated.
This maintenance is accomplished.