Get webhook notifications whenever Network & Infrastructure creates an incident, updates an incident, resolves an incident or changes a component status.
We had a hardware dysfunction on this equipment. No impact on traffic but no change was possible. We are continuing to investigate with supplier.
Update(s):
Date: 2016-03-02 15:15:03 UTC The card was inserted and no impact was found. This card is in standby mode at this time.
We continue to investigate with our supplier.
Date: 2016-03-02 15:14:14 UTC We will reinsert the card.
Date: 2016-03-02 15:13:52 UTC The faulty card was removed forcing the switching on the CPU card in standby. No impact was found and the service is currently standardized.
We will diagnose the faulty card with the manufacturer to evaluate whether a hardware replacement is necessary.
Date: 2016-03-02 15:09:34 UTC We have detected the following logs on the CPU card:
2016-03-02T06:31:37+01:00 37.187.231.14 gra-3b-a9.fr.eu 96268 bc [local7.warning] === 96268: RP/0/RSP0/CPU0:Mar 2 06:31:37.546 CET: dhcpd[1086]: %IP-DHCPD-4-INVALID_DEFAULT_GATEWAY : Invalid! default gateway, Client(0025.90a4.70ec) Release/Renew send may fail
2016-03-02T06:18:06+01:00 37.187.231.14 gra-3b-a9.fr.eu 96263 ba [local7.crit] === 96263: RP/0/RSP0/CPU0:Mar 2 06:18:06.686 CET: pfm_node_rp[360]: %PLATFORM-AHCI-2-DEV_HD0_NOT_RESPONDING : Set|ahci-mon[36890]|0x1000000|HD0 device not responding
This seems to be a hardware issue on the card. We are removing it in order to switch to the redundant CPU card.