FS#16594 — rbx6-10b-n6
Incident Report for Network & Infrastructure
Resolved
half of the chassis is failing, we will reboot.
traffic is forwarded through A.

rbx6-10b-n6# sh int status

--------------------------------------------------------------------------------
Port Name Status Vlan Duplex Speed Type
--------------------------------------------------------------------------------
Eth1/1 vss-10b-6k faulty trunk full 10G --
Eth1/2 vss-10a-6k faulty trunk full 10G --
Eth1/3 fex 100|EG-MG faulty 1 full 10G --
Eth1/4 -- faulty 1 full 10G --
Eth1/5 fex 101|EG-MG faulty 1 full 10G --
Eth1/6 -- faulty 1 full 10G --
Eth1/7 fex 102|EG-MG faulty 1 full 10G --
Eth1/8 -- faulty 1 full 10G --
Eth1/9 fex 103|EG-MG faulty 1 full 10G --
Eth1/10 fex 111|ASA faulty 1 full 10G --
Eth1/11 -- faulty 1 full 10G --
Eth1/12 -- faulty 1 full 10G --
Eth1/13 fex 104|EG-MG faulty 1 full 10G --
Eth1/14 -- faulty 1 full 10G --
Eth1/15 fex 105|EG-MG faulty 1 full 10G --
Eth1/16 -- faulty 1 full 10G --
Eth1/17 fex 106|EG-MG faulty 1 full 10G --
Eth1/18 -- faulty 1 full 10G --
Eth1/19 fex 107|EG-MG faulty 1 full 10G --
Eth1/20 -- faulty 1 full 10G --
Eth1/21 -- faulty 1 full 10G --
Eth1/22 -- faulty 1 full 10G --
Eth1/23 fex 108|EG-MG faulty 1 full 10G --
Eth1/24 -- faulty 1 full 10G --
Eth1/25 fex 109|EG-MG connected 1 full 10G Fabric Exte
Eth1/26 -- sfpAbsent 1 full 10G --
Eth1/27 fex 110|EG-MG connected 1 full 10G Fabric Exte
Eth1/28 -- sfpAbsent 1 full 10G --
Eth1/29 fex 112|EG-MG connected 1 full 10G Fabric Exte
Eth1/30 -- sfpAbsent 1 full 10G --
Eth1/31 fex 113|EG-MG connected 1 full 10G Fabric Exte

Update(s):

Date: 2016-02-15 15:15:51 UTC
All fex are up.

rbx6-10b-n6# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
100 fex100 Online N2K-C2248TP-E-1GE SSI17250JP9
101 fex101 Online N2K-C2248TP-E-1GE SSI173606H7
102 fex102 Online N2K-C2248TP-E-1GE FOX1749GXM8
103 fex103 Online N2K-C2248TP-E-1GE SSI1802020N
104 fex104 Online N2K-C2248TP-E-1GE SSI1802074Y
105 fex105 Online N2K-C2248TP-E-1GE SSI172304A1
106 fex106 Online N2K-C2248TP-E-1GE SSI180200KH
107 fex107 Online N2K-C2248TP-E-1GE SSI1802026D
108 fex108 Online N2K-C2248TP-E-1GE SSI180201YE
109 fex109 Online N2K-C2248TP-E-1GE SSI17410414
110 fex110 Online N2K-C2248TP-E-1GE SSI1802024B
111 fex111|ASA Online N2K-C2248TP-E-1GE SSI173605X8
112 fex112 Online N2K-C2248TP-E-1GE SSI173606HW
113 fex113 Online N2K-C2248TP-E-1GE SSI1741044C
114 fex114 Online N2K-C2248TP-E-1GE SSI173605MB
115 fex115 Online N2K-C2248TP-E-1GE SSI18020751
116 fex116 Online N2K-C2248TP-E-1GE SSI174106G0
117 fex117 Online N2K-C2248TP-E-1GE FOX1748GLZ1
118 fex118 Online N2K-C2248TP-E-1GE FOX1750GQJB
119 fex119 Online N2K-C2248TP-E-1GE FOX1750GJ2T
120 fex120 Online N2K-C2248TP-E-1GE SSI181709Z8
rbx6-10b-n6# sh system internal mts buffers
MTS buffers in use = 468

Date: 2016-02-15 15:15:29 UTC
bx6-10b-n6# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
100 fex100 Online N2K-C2248TP-E-1GE SSI17250JP9
101 fex101 Online N2K-C2248TP-E-1GE SSI173606H7
102 fex102 Online N2K-C2248TP-E-1GE FOX1749GXM8
103 fex103 Online N2K-C2248TP-E-1GE SSI1802020N
104 fex104 Online N2K-C2248TP-E-1GE SSI1802074Y
105 fex105 Online N2K-C2248TP-E-1GE SSI172304A1
106 fex106 Online N2K-C2248TP-E-1GE SSI180200KH
107 fex107 Online N2K-C2248TP-E-1GE SSI1802026D
108 fex108 Online N2K-C2248TP-E-1GE SSI180201YE
109 fex109 Online N2K-C2248TP-E-1GE SSI17410414
110 fex110 Online N2K-C2248TP-E-1GE SSI1802024B
111 fex111|ASA Online N2K-C2248TP-E-1GE SSI173605X8
112 fex112 Online N2K-C2248TP-E-1GE SSI173606HW
113 fex113 Online N2K-C2248TP-E-1GE SSI1741044C
114 fex114 Online N2K-C2248TP-E-1GE SSI173605MB
115 fex115 Online N2K-C2248TP-E-1GE SSI18020751
116 fex116 Online N2K-C2248TP-E-1GE SSI174106G0
117 fex117 Online N2K-C2248TP-E-1GE FOX1748GLZ1
rbx6-10b-n6#
rbx6-10b-n6# sh system internal mts buffers
MTS buffers in use = 264

still 3 more fex to get up.

Date: 2016-02-15 15:14:46 UTC
rbx6-10b-n6# sh system internal mts buffers
MTS buffers in use = 982
rbx6-10b-n6#
rbx6-10b-n6#
rbx6-10b-n6# sh system internal mts buffers
MTS buffers in use = 1003
rbx6-10b-n6#
rbx6-10b-n6# sh system internal mts buffers
MTS buffers in use = 1000

Date: 2016-02-15 15:14:34 UTC
rbx6-10b-n6# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
100 fex100 Online N2K-C2248TP-E-1GE SSI17250JP9
101 fex101 Online N2K-C2248TP-E-1GE SSI173606H7
102 fex102 Online N2K-C2248TP-E-1GE FOX1749GXM8
103 fex103 Online N2K-C2248TP-E-1GE SSI1802020N
104 fex104 Online N2K-C2248TP-E-1GE SSI1802074Y
105 fex105 Online N2K-C2248TP-E-1GE SSI172304A1
106 fex106 Online N2K-C2248TP-E-1GE SSI180200KH
rbx6-10b-n6#
rbx6-10b-n6#
rbx6-10b-n6# sh system internal mts buffers
MTS buffers in use = 211


+ 3 fex and the use buffers explodes....

Date: 2016-02-15 15:13:08 UTC
Up.

The VPC is also up and running. We are nor taking care of the fex.

rbx6-10b-n6#
rbx6-10b-n6# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial

Date: 2016-02-15 15:13:08 UTC
Up.

The VPC is also up and running. We are nor taking care of the fex.

rbx6-10b-n6#
rbx6-10b-n6# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
--- -------- Connected N2K-C2248TP-E-1GE SSI173606H7
--- -------- Connected N2K-C2248TP-E-1GE SSI17250JP9
rbx6-10b-n6#
rbx6-10b-n6#
rbx6-10b-n6# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
100 fex100 Connected N2K-C2248TP-E-1GE SSI17250JP9
101 fex101 Online Sequence N2K-C2248TP-E-1GE SSI173606H7
102 fex102 Connected N2K-C2248TP-E-1GE FOX1749GXM8
rbx6-10b-n6#

Date: 2016-02-15 15:12:08 UTC
int po100-120
shut


rbx6-10b-n6#
rbx6-10b-n6# reload
WARNING: This command will reboot the system
Do you want to continue? (y/n) [n] y
Posted Feb 15, 2016 - 15:11 UTC